Ir directamente a la información del producto
1 de 8

Original SmartGen HGM9510 Diesel Generator Set Controller Parallel Drive Control Module with 4.3 inches TFT-LCD

Original SmartGen HGM9510 Diesel Generator Set Controller Parallel Drive Control Module with 4.3 inches TFT-LCD

Test before shippment, 1 year warranty, pay safe with PayPal. Free Shipping to 63 countries.

Precio habitual $950.00
Precio habitual Precio de oferta $950.00
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.
HGM9510 controller is designed for manual/auto parallel system generators with similar or different capacity. Additionally, it is suitable for single unit constant power output and mains paralleling. It allows automatic start/stop, parallel running, data measurement, alarm protection as well as remote control, remote measurement and remote communication function. It fits with LCD display, optional Chinese, English and other languages interface, and it is reliable and easy to use.

Performance and Characteristics

With ARM-based 32-bit SCM, high integration of hardware and more reliable;
480x272 LCD with backlight, multilingual interface (including English, Chinese or other languages) which can be chosen at the site, making commissioning convenient for factory personnel;
Improved LCD wear-resistance and scratch resistance due to hard screen acrylic;
Silicon panel and pushbuttons for better operation in high/low temperature environment;
RS485 communication port enables remote control, remote measuring, remote communication via ModBus protocol;
Fitted with CANBUS port and can communicate with J1939 genset. Not only can you monitor frequently-used data (such as water temperature, oil pressure, engine speed, fuel consumption and so on) of ECU machine, but also control start, stop, raising speed and speed droop via CANBUS port;  Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120/240V and frequency 50/60Hz;
Collects and shows 3-phase voltage, current, power parameter and frequency of Bus/Gens;
For Bus, controller has loss of phase and reverse phase sequence detection functions; For generator, controller has over voltage, under voltage, over frequency, under frequency, over current, over power, reverse power, loss of phase, reverse phase sequence detection functions;
Synchronization parameters: Voltage Difference Between Bus and Gens, Frequency Difference Between Bus and Gens, Phase Difference Between Bus and Gens;
Multiple running modes in auto state: with load running, off load running, demand parallel running;
Ramp on and ramp off function;
3 fixed sensors (temperature, oil pressure and liquid level);
2 configurable sensors can be set as sensor of temperature, oil pressure or fuel level;
More kinds of curves of temperature, oil pressure, fuel level can be used directly and users can define the sensor curves by themselves;
Ver todos los detalles

Send Inquiries