Не удалось загрузить сведения о доступности самовывоза
2.8 inch LCD screen display with brand new UI design is adapted in this controller that the relative failures can be displayed directly. All the parameters can be displayed by simulated indicators and words. Besides, LCD screen can display various faults in the same time that the genset will be stopped once it can’t work smoothly.
StandardCAN communication port, built-in J1939 protocol, has matched more than 40 kinds of engines;
Parameters Display
Engine RPM
Engine oil pressure
Engine temperature
Engine fuel level
Engine battery voltage
Charging voltage
CAN related parameters(C series only)
Mains Frequency (only for DC42C)
Mains phase voltage L-N (only for DC42C)
Mains phase voltage L-L (only for DC42C)
Generator 3 Phase voltage L-N
Generator 3 Phase voltage L-L
Generator 3 phase current A
Generator Frequency Hz
Generator Power Factor COS φ
Generator active power KW
Generator apparent power KVA
Generator reactive power KVar
Real-time load rate %
Current load rate %
Average loading rate %
Current consumption KWH
Total consumption KWH
Total Crank times
Cumulative power on time of controller
Current running time
Total running time
Maintenance notice
Switches input status display
Output status display of relays
Current date and time;
Protection
Over speed
Under speed
Low oil pressure
High temperature
Low fuel level
External emergency alarm
D+ open
RPM Lost
Sensor Open
Over Frequency
Under Frequency
Over voltage
Under voltage
Over current
Non-balance of current
Overpower
Maintenance expire
Low water level alarm
Emergency Stop
Crank failure
Battery over voltage
Battery under voltage
The charger fails to charge
Charger charging failure
Stop Failure
ECU alarm failure
ECU communication Failure
Options
Parameters
Working voltage
DC8V----36V Continuous
Power consumption
Standby:24V:MAX 2W
Working:24V:MAX5W
AC Voltage Input
1P2W 30VAC-276VAC (ph-N)
2P3W 30VAC-276VAC (ph-N)
3P4W 30VAC-276VAC (ph-N)
MAX Accumulating Time
99999.9Hours(Min Store time:6min)
Fuel Relay Output
Max 5Amp DC+VE Supply voltage
Start Relay Output
Max 5Amp DC+VE Supply voltage
AUX.OUTPUT 1
Max 1Amp DC+VE Supply voltage
AUX.OUTPUT 2
Max 1Amp DC+VE Supply voltage
AUX.OUTPUT 3
Max 1Amp DC+VE Supply voltage
AUX.OUTPUT 4
Max 1Amp DC+VE Supply voltage
Excitation output
Max 0.9AMP DC+VE supply voltage
AUX. Input
Available if connecting with Battery -
Working condition
-25-65℃
Storage condition
-40-85℃
Protection Level
IP54:when waterproof rubber gasket is added between controller and its panel
Insulation strength
Apply AC2.2kV voltage between high voltage terminal and low voltage terminal; The leakage current is not more than 3mA within 1min.