The 650-045 Printed Circuit Board for gensets OLYMPLAN-MASSEY FERGUSON 24V.
Ensure the MPU (Magnetic Pickup) is installed correctly.
Unscrew and pull out the magnetic pickup that is located near the flywheel of the engine
ย Inspect the magnetic tip and ensure that it is clean and free of debris.
Screw the MPU in until the tip makes contact with the top of the flywheel teeth.
ย Back out the magnetic pickup ยฝ to ยพ of a turn.
EIM (Engine Interface Module)
Turn the ten-turn potentiometer between five to seven turns clockwise or just until you feel a small click - signifying the full span of the pot.
Start the generator set. You will notice the overspeed calibration LED illuminated.
Slowly turn the potentiometer counter-clockwise until the LED just turns off.
As soon as the LED turns off, start to slowly turn back the potentiometer clockwise just until the led starts to flicker.