Langsung ke informasi produk
1 dari 7

HAT520N ATS Controller Automatic Transfer Switch Generator Set Dual Power Supply Automatic Switch Genset Part

HAT520N ATS Controller Automatic Transfer Switch Generator Set Dual Power Supply Automatic Switch Genset Part

Test before shippment, 1 year warranty, pay safe with PayPal. Free Shipping to 63 countries.

Harga reguler $97.00
Harga reguler Harga obral $97.00
Obral Habis
Biaya pengiriman dihitung saat checkout.
HAT520N/530N Dual Power ATS Controller is made by the core of the microprocessor, which can precisely detect 2-way 3-phase voltages, 2-way single phase voltages and make accurate judgment for the occurred abnormal voltages (lost of power, over voltage, under voltage, over frequency, under frequency, loss of phase, phase sequence wrong), controlling ATS switchover after delay. It is suitable for controlling No Breaking ATS, and it has the function of issuing genset start signal after abnormal delay of one way. By LINK communication port, "three remotes" (remote measurement, remote communication and remote control) function can be realized.

Performance and Characteristics

It has the following characteristics:
— Measure and display 2-way 3-phase Voltage and Frequency:
1# Line
voltage (Uab, Ubc, Uca)
Phase voltage (Ua, Ub, Uc)
Frequency Hz
2#Line
voltage (Uab, Ubc, Uca)
Phase voltage (Ua, Ub, Uc)
Frequency Hz
— Over/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function.
As default, phase sequence wrong protection and over/under frequency protection are disabled;
however, users can set the protection function as you need.
— LINK communication port (SmartGen SG72 adapter is needed), with which controller parameters can
be set and firmware update also can be realized. — The voltage normal delay of 1# or 2# can be set (Range: 0s~60s) and Genset start delay can be set
(Range: 0s~3600s).
— The voltage abnormal delay of 1# or 2# can be set (Range: 0s~60s) and Genset stop delay can be
set (Range: 0s~3600s).
— “1# Master”, “Each Backup” and “2# Master” can be set via controller front panel, so that 1# power
master supply, or 2# power master supply, or mutual backup power supply for each other can be
realized.
— Close output signal can be set as pulse or continuous output.
— 2-way N-wire isolated design.
— Auto/Manual mode transfer. In manual mode, ATS transfer 1# switch or 2# switch can be
implemented via panel pushbutton.
— LEDs mounted on front panel can clearly show ATS running status.
— The output contactor capacity of 1# and 2# power transfer relay (1# CLOSE, 2# CLOSE) is 16A
AC250V, volts-free contact, which can be directly used in driving switch to transfer.
— The output contactor capacity of Genset start relay (GENS START) is 7A AC250V/7A DC28V,
volts-free N/C contact.
— Suitable for various AC systems (3-phase 4-wire, 2-phase 3-wire and single-phase 2-wire).
— Modular design, flame retardant ABS plastic shell, pluggable terminal, built-in mounting, compact
structure with easy installation.
Lihat detail lengkap

Send Inquiries