Test before shippment, 1 year warranty, pay safe with PayPal. Free Shipping to 63 countries.
Performance and Characteristics
132x64 LCD with backlight, selectable language interface (Chinese, English, Spanish, Turkish, Russian and French), push-button operation;
Improved LCD wear-resistance and scratch resistance due to hard screen acrylic;
Silicon panel and pushbuttons for better operation in high/low temperature environment;
Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120/240V and frequency 50/60Hz;
Collects and shows 3-phase voltage, 3-phase current, power parameter and frequency of generator or mains. For Mains, controller has over voltage, under voltage and loss of phase detection functions; Forgenerator, controller has over voltage, under voltage, over frequency, under frequency, over current and over power detection functions;
Control and protection function: automatic start/stop of the genset, ATS (Auto Transfer Switch) control and perfect fault indication and protection function;
ETS (Energize To Stop), idle control, pre-heat control, speed raise control and speed drop control functions, and all output ports are relay outputs;
Parameter setting function: allows users to modify and set the parameters and meanwhile will be stored in internal FLASH and won't be lost even in case of power outage; all controller parameters can be adjusted on front panel of the controller or via USB interface on PC.
Multiplex input port 3 and 4 can be used in various occasions: input 3 can be used as auxiliary input port or fuel level sensor, while input 4 can be used as auxiliary input port or configurable sensor.
Multiple temperature, oil pressure, and fuel level sensors can be used directly, and parameters can be users-defined.
One configurable sensor: can be set to temperature sensor, oil pressure sensor or fuel level sensor, which enables the detection of double temperatures, double oil-pressures and double fuel levels.
Multiple crank disconnect conditions (magnetic pickup, oil pressure, generator) are optional;
Emergency start function; Fly teeth auto-recognition function;
Wide power supply range: DC(8~35)V, which suitable for different starter battery voltage environments.
All parameters apply digital adjustment, instead of conventional analog modulation with normal potentiometer, improving the wholesome reliability and stability;
Maintenance function: types can be set to date or running time. Actions (warning, alarm shutdown) can also be set when maintenance time is out;
Event log function (max. 99 pieces of records), real-time clock, and schedule to start/stop generator function (start once monthly/weekly/daily on/off load can be set).
IP55 waterproofness with rubber-ring gasket between enclosure and screen; Metal fixing clips are used to fix the controller;
Modular design, self-extinguished ABS plastic enclosure, pluggable connection terminals and embedded installation way; compact structure with easy mounting.